Component: Digital Potentiometer (MCP45XX MCP46XX) (Analog Output)

From Flowcode Help
Jump to navigationJump to search


Author Matrix TSL
Version 1.0 (Release)
Category Analog Output


Image Digital Potentiometer (MCP45XX MCP46XX) component

The MCP45XX and MCP46XX device range supports up to 2 digital potentiometers or rheostat outputs. 129 or 257 possible output resistance values for each channel.

Examples

No additional examples


Downloadable macro reference

IncrementWiper

Increments a single volatile wiper value

Parameters

BYTE Index
Range: 0-3


Return value

This call does not return a value


DecrementWiper

Decrements a single volatile wiper value

Parameters

BYTE Index
Range: 0-1


Return value

This call does not return a value


SetWiper

Sets the value of a single wiper

Parameters

BYTE Index
Range: 0-3
UINT Value
129 Taps Range: 0-128 / 257 Taps Range: 0-256
BOOL MemoryType
0=Volatile, 1=Nonvolatile


Return value

This call does not return a value


ReadAddress

Reads a value from one of the registers on the device

Parameters

BYTE Address
Range: 0-15


Return value

UINT


WriteAddress

Writes a value to one of the registers on the device

Parameters

BYTE Address
Range: 0-15
UINT Value
Range: 0-256


Return value

This call does not return a value


Initialise

Startup the I2C peripheral ready for communications.

Parameters

This macro has no parameters


Return value

This call does not return a value

Simulation macro reference

This component does not contain any simulation macros


Property reference

Channel

This property is of type Fixed list of ints and can be referenced with the variable name cal_i2c1::CHANNEL.

Channel selection

SDA

This property is of type Single digital pin and can be referenced with the variable name cal_i2c1::SDA.

Pin used for SDA (data signal)

SCL

This property is of type Single digital pin and can be referenced with the variable name cal_i2c1::SCL.

Pin used for SCL (clock signal)

Baud Select

This property is of type Fixed list of ints and can be referenced with the variable name cal_i2c1::BAUD_LIST.

Baud rate option selector

Baud Rate

This property is of type Signed integer and can be referenced with the variable name cal_i2c1::BAUD.

Baud rate to be used

Stop Delay

This property is of type True or false and can be referenced with the variable name cal_i2c1::StopDel.

On older microcontroller devices there is a potential for the I2C hardware channel to lock up if there is not

a 10ms delay between an I2C stop event and the next I2C start event.


Most modern microcontrollers will not have a problem so this property can be disabled to speed up the

I2C communications.

Number of Outputs

This property is of type Fixed list of ints and can be referenced with the variable name NumOutputs.

No additional information


Number of Taps

This property is of type Fixed list of ints and can be referenced with the variable name NumTaps.

No additional information


Address Bits

This property is of type Fixed list of ints and can be referenced with the variable name AddressBits.

No additional information


Simulate Comms

This property is of type True or false and can be referenced with the variable name SimulateComms.

No additional information


Scope Traces

This property is of type True or false and can be referenced with the variable name cal_i2c1::ScopeTraces.

Selects if the component pin connections are automatically generated on the data recorder window or not.

Yes: Automatically add the component pins to a group on the data recorder which will reflect the sim data during simultion.

No: Do not show the pin signals on the data recorder window.

Console Data

This property is of type True or false and can be referenced with the variable name cal_i2c1::ConsoleData.

Selects if the console data is automatically generated or not

Injector

This property is of type Fixed list of ints and can be referenced with the variable name cal_i2c1::Injector.

Specifies the injector component on the panel to interact with to provide comms simulation.