Uses a high speed SPI connection to enable up to four buffered external UARTs via the MULTIUART modules.


Examples

FC6 Icon.png Simple test program


Downloadable macro reference

ReceiveByte

Returns the first received byte held in queue for the selected channel.

Recommended to use the CheckRx macro first to collect number of bytes.

Parameters

BYTE UART
UART Index Range: 0-3


Return value

BYTE


TransmitString

Adds a byte to the transmit queue for the selected channel.

Parameters

BYTE UART
UART Index Range: 0-3
<- STRING Data
This parameter may be returned back to the caller


Return value

This call does not return a value


SetBaud

Adds a byte to the transmit queue for the selected channel.

Parameters

BYTE UART
UART Index Range: 0-3
BYTE Baud
0=1200, 1=2400, 2=4800, 3=9600, 4=19200, 5=38400, 6=57600, 7=115200


Return value

This call does not return a value


TransmitByte

Adds a byte to the transmit queue for the selected channel.

Parameters

BYTE UART
UART Index Range: 0-3
BYTE Data


Return value

This call does not return a value


CheckRx

Returns the number of received bytes held in queue for the selected channel.

Parameters

BYTE UART
UART Index Range: 0-3


Return value

BYTE


ReceiveString

Returns a string of received bytes held in queue for the selected channel.

Recommended to use the CheckRx macro first to collect number of bytes.

Parameters

BYTE UART
UART Index Range: 0-3
BYTE NumBytes


Return value

STRING


CheckTx

Returns the number of bytes held in the transmit queue for the selected channel.

Parameters

BYTE UART
UART Index Range: 0-3


Return value

BYTE


Initialise

Activates the SPI peripheral and claims control over the I/O pins.

Parameters

This macro has no parameters


Return value

This call does not return a value


Simulation macro reference

This component does not contain any simulation macros


Property reference

Channel

This property is of type Fixed list of ints and can be referenced with the variable name cal_spi::CHANNEL.

SPI Channel selector

Prescale

This property is of type Fixed list of ints and can be referenced with the variable name cal_spi::PR_SCALE.

Prescale option selector

MOSI

This property is of type Single digital pin and can be referenced with the variable name cal_spi::MOSI.

SPI Data Out Pin SDO - Also Known as Master Out Slave In (MOSI) when used in Master mode.

MISO

This property is of type Single digital pin and can be referenced with the variable name cal_spi::MISO.

SPI Data In Pin SDI - Also Known as Master In Slave Out (MISO) when used in Master mode.

CLK

This property is of type Single digital pin and can be referenced with the variable name cal_spi::CLK.

SPI Clock Pin CLK - The Clock signal is driven by the SPI master.

CS / SS

This property is of type Single digital pin and can be referenced with the variable name cal_spi::SS.

Chip Select / Slave Select Pin

Master Mode: General purpose output pin used to select the remote SPI device.

Slave Mode: Hardware chip select pin input used to select the SPI device.

Label

This property is of type Line of text and can be referenced with the variable name label.

Label used to identify the component on the panel.

Scope Traces

This property is of type True or false and can be referenced with the variable name cal_spi::ScopeTraces.

Selects if the scope traces are automatically generated or not

Console Data

This property is of type True or false and can be referenced with the variable name cal_spi::ConsoleData.

Selects if the console data is automatically generated or not

Injector

This property is of type Fixed list of ints and can be referenced with the variable name cal_spi::Injector.

No additional information